Direct-Fired Controls

Controls for direct-fired air handlers offer a wide variety of options. Both HVAC and SPRAY-CURE™ remote panels are pre-engineered for ease of use. All remote panels are constructed within a NEMA 1 enclosure. HVAC panels are used for make-up air space heating. SPRAY-CURE™ panels can be used for spray booths, cure applications or spray/cure finishing areas. Analog and digital remote panels are available. 
 
An alternative to a standard remote panel offering is a BMS-Ready control package. This option provides inputs to receive control signals from a customer determined control system. Each BMS input is capable of receiving a 4-20mA or 0-10VDC from the control system. Every package includes fan on/off relay, burner on/off relay, flame failure relay and signal conditioner for burner modulation. For optimum efficiency, Bananza suggests to limit the discharge temperature to 160°F.

 

HVAC Remote Panels

Basic Remote Panel

Basic Remote Panel

Standard Discharge Control Remote

Standard Discharge Control Remote

Deluxe Temperature Control Remote

Deluxe Temperature Control Remote

This control is used for make-up air and space heating. The discharge temperature of the heater remains constant as selected on the selection dial. The burner flame is modulated by a discharge temperature control, which is governed by the remote temperature selector.

FAN ON  / BURNER ON mode:
Heater can operate continuously for building exhaust air replacement and space heating by maintaining a constant discharge temperature.

FAN ON / BURNER OFF mode:
The blower can operate without the burner for summer ventilation.

This control is used for make-up air and day/night heating of the building. The discharge temperature of the heater remains constant as selected on the selection dial. The burner flame is modulated by a discharge temperature control, which is governed by the remote temperature selector. 

AUTO / WINTER mode:
Heater cycles on/off to maintain space temperature as selected on the thermostat.

ON / WINTER mode:
Heater can operate continuously for building exhaust air replacement and space heating by maintaining a constant discharge temperature.

ON / SUMMER mode:
The blower can operate without the burner for summer ventilation.

This control is used for make-up air and total automatic "day/night" heating of the building. A solid-state modulating room Selectrastat fully modulates the burner flame to maintain space temperature and compensate for changing building heat losses or gains. 

AUTO / WINTER mode:
Occupied time: Heater can operate continuously fully modulating Btu/h output to maintain space temperature as selected on the Selectrastat. 
Unoccupied time: Heater cycles on/off to maintain space temperature as selected on the programmable thermostat (night setback).

ON / WINTER mode:
Heater can operate continuously fully modulating Btu/h output to maintain space temperature as selected on the Selectrastat.

ON / SUMMER mode:
The blower can operate without the burner for summer ventilation.

SPRAY-CURE™ Remote Panels

Basic II Spray Remote

Basic II (Spray) Remote

Basic II Cure Remote

Basic II (Cure) Remote

Dual #2 Remote

Dual #2 Remote

This control is used for spraying paint with discharge air temperature from 55°F to 90°F. Discharge temperature of heater remains constant as selected on temperature selection dial. Burner flame is modulated by discharge temperature control, which is governed by remote temperature selector. ON/OFF switch for booth lights. 

FAN ON / BURNER ON mode:
Heater operates continuously, supplying make-up air and maintaining a constant discharge temperature.

FAN ON / BURNER OFF mode:
Blower can operate without burner for cool down. 

This control is used for curing paint with discharge air temperature from 120°F to 170°F. Discharge temperature of the heater remains constant as selected on temperature selection dial. Burner flame is modulated by discharge temperature control, which is governed by remote temperature selector. ON/OFF switch for booth lights.

FAN ON / BURNER ON mode:
Heater operates continuously, supplying make-up air and maintaining a constant discharge temperature. 

FAN ON / BURNER OFF mode:
Blower can operate without burner for cool down.

This control system incorporates ON/OFF switches and indicator lights for fan, burner and booth lights; SPRAY-CURE™ mode selector switch and indicator light; two discharge temperature selection dials (55°F-90°F and 120°F-170°F); adjustable timers for PURGE and CURE cycle and cure interlock relay.

FAN / BURNER / BOOTH LIGHT ON - SPRAY mode:
Heater operates continuously, supplying make-up air. Burner modulates maintaining a constant discharge temperature (55°F-90°F)

SPRAY-CURE™ Selector switched to CURE mode:
PURGE timer (adjustable) is energized. CURE timer (adjustable) is energized. BOOTH LIGHTS turn off. Temperature control switches to CURE selector (120°F-170°F). Burner modulates maintaining a constant discharge temperature. COOL down timer (preset) is energized. BOOTH LIGHTS turn ON. Temperature control switches to SPRAY selector (55°F-90°F). Burner modulates maintaining a constant discharge temperature. Heater turns off.

 

Digital Dual #1 Remote

Digital Dual #1 Remote

Deluxe Digital 60-160 Remote

Digital 60-160 Remote

BAMS Deluxe Digital Remote

BAMS Deluxe Digital Remote

This control system incorporates ON/OFF switches and indicator lights for fan and burner; SPRAY-CURE™ mode selector switch and indicator light; two discharge temperature selection dials (60°F-90°F and 80°F-180°F) with digital display; adjustable speed controls for exhaust fan in spray and cure mode and cure interlock relay. 

FAN / BURNER ON - SPRAY mode:
Heater operates continuously, supplying make-up air. Burner modulates maintaining a constant discharge temperature (60°F-90°F). Spray speed pots adjusts booth pressure.

FAN / BURNER ON - CURE mode:
Temperature control switches to CURE selector (80°F-180°F). Burner modulates maintaining a constant discharge temperature. Cure speed pot adjusts booth pressure.

This control system incorporates ON/OFF switches and indicator lights for fan, burner and booth lights; discharge temperature selection dial (60°F-160°F) with digital display; adjustable speed control for exhaust fan and booth pressure gauge. Optional items include burner lockout and check filter indicator light and remote reset push button. 

FAN / BURNER / BOOTH LIGHT ON mode: 
Heater operates continuously, supplying make-up air. Burner modulates maintaining a constant discharge temperature (60°F-160°F). The booth pressure can be adjusted via the speed pit and observed on the pressure gauge.

This control system incorporates ON/OFF switches and indicator lights for fan, burner and booth lights; SPRAY-CURE™ mode selector switch and indicator light; tow discharge temperature selection dials (60°F-90°F and 80°F-180°F) with digital display; adjustable timers for PURGE and CURE cycle; adjustable cool down timer; adjustable speed controls for exhaust fan in spray and cure mode; booth pressure gauge and cure interlock relay. Optional items include burner lockout and check filter indicator light and remote reset push button.

FAN / BURNER / BOOTH LIGHT ON - SPRAY mode:
Heater operates continuously, supplying make-up air. Burner modulates maintaining a constant discharge temperature (60°F-90°F). Spray speed pot adjusts booth pressure.

SPRAY-CURE™ Selector Switched to CURE mode:
PURGE timer (adjustable) is energized. CURE timer (adjustable) is energized. BOOTH LIGHTS turn OFF. Temperature control switches to CURE selector (80°F-180°F). Burner modulates maintaining a constant discharge temperature. Cure speed pot adjusts booth pressure. COOL down timer (preset) is energized. BOOTH LIGHTS turn ON. Temperature control switches to SPRAY selector (60°F-90°F). Burner modulates maintaining a constant discharge temperature. Spray speed pot adjusts booth pressure. Heater turns off.