Model | 40 | 60 | 80 | 100 | 125 | 150 | 175 | 200 |
Min. Straight Tube Length |
10 | 20 | 20 | 30 | 40 | 40 | 50 | 50 |
Min. U-Tube Length |
11,6 | 11,6 | 11,6 | 16,6 | 21,6 | 21,6 | 26,6 | 26,6 |
Overall Min. Tube Length |
12,3 | 22,3 | 22,3 | 32,3 | 42,3 | 42,3 | 52,5 | 52,5 |
Overall Min. U-Tube Length |
13,2 | 13,2 | 13,2 | 18,2 | 23,2 | 23,2 | 28,2 | 28,2 |
Model | 40 | 60 | 80 | 100 | 125 | 150 | 175 | 200 |
Inlet Pressure (NG min) |
4.6 | 4.6 | 4.6 | 4.6 | 4.6 | 4.6 | 5 | 5 |
Inlet Pressure (LPG Propane min) |
11 | 11 | 11 | 11 | 11 | 11 | 11 | 11 |
Inlet Pressure (NG & LPG Propane max) |
14 | 14 | 14 | 14 | 14 | 14 | 14 | 14 |
Gas Connect (NPT) |
½" | ½" | ½" | ½" | ½" | ¾" | ¾" | ¾" |
Tube & Accessory Pkg. Length (ft) |
10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 |
Hot Rolled or Aluminized Tube w/ Alum. Reflector (lb) |
52 | 86 | 120 | 161 | 206 | 240 | 281 | 322 |
Aluminized Tube w/ Stainless Reflector (lb) |
66 | 113 | 152 | 208 | 265 | 304 | 360 | 416 |
Burner |
35 | |||||||
Alumn. U-Tube w/ Alumn. End Caps |
19 | |||||||
Alumn. U-Tube w/ Stainless End Caps |
20 |
Fuel |
NG or LPG Propane |
Electrical Supply |
120V,60Hz,1A |
Heat Exchanger Tube |
10 ft Sections, 4" dia, 16 Gauge, First 10 ft ALUMI-THERM® Steel Tubing [Remaining Hot Rolled or Heat Treated Aluminized Tubing] |
Exhaust Flue (dia.) |
4" |
Reflector and End Caps |
.024 Aluminum [Optional - .024 Stainless Steel Type 304] |
Control System |
Fully Automatic, Three-Try, 100% Shut-Off, Direct Spark Electronic Ignition Control |
Approved as |
Indoor (Vented or Unvented) |
Certification |
ANSI Z83.20/CSA 2.34, 2.17 |
Warranty |
Three-Year Limited (Refer to Installation, Operation and Service Manual for Details) |
Model | 40 | 60 | 80 | 100 | 125 | 150 | 175 | 200 |
Radiant Tube Length |
20 | 30 | 30 | 40 | 50 | 50 | 60 | 60 |
Dist. From Burner to Elbow |
10 | 10 | 10 | 15 | 15 | 20 | 20 | 20 |
Elbows Allowed Per Burner |
2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Number of Burners
|
4 | 4 | 4 | 4 | 4 | 3 | 2 | 2 |
Number of Burners
|
6 | 6 | 6 | 6 | 6 | 5 | 4 | 4 |
Number of Burners
|
16 | 16 | 14 | 12 | 12 | 10 | 8 | 8 |
Model | 40 |
60 |
80 |
100 |
125 |
150 |
175 |
200 |
||||||||
| * | Hrz. |
45° |
Hrz. |
45° |
Hrz. |
45° |
Hrz. |
45° |
Hrz. |
45° |
Hrz. |
45° |
Hrz. |
45° |
Hrz. |
45° |
A | 5 |
8 |
5 |
8 |
5 |
9 |
5 |
10 |
5 |
10 |
5 |
10 |
8 |
10 |
8 |
10 |
B | 20 |
4 |
27 |
4 |
30 |
4 |
32 |
4 |
35 |
4 |
39 |
4 |
44 |
4 |
47 |
4 |
C | 41 |
35 |
51 |
45 |
58 |
54 |
60 |
57 |
65 |
63 |
71 |
66 |
74 |
69 |
76 |
73 |
D | 20 |
43 |
27 |
45 |
30 |
55 |
32 |
56 |
35 |
58 |
39 |
61 |
44 |
68 |
47 |
71 |
Installation Code and Annual Inspections:
All installations and service of BANANZA® equipment must be performed by a contractor qualified in the installation and service of equipment sold and supplied by Bananza and conform to all requirements set forth in the BANANZA® manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate optimum performance and safety, Bananza recommends that a qualified contractor annually inspect your BANANZA® equipment and perform service where necessary, using only replacement parts sold and supplied by Bananza.
Further Information:
Applications, engineering and detailed guidance on systems design, installation and product performance is available through BANANZA® representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual.
BANANZA® products are not for residential use.
BANANZA® documents are intended to assist licensed professionals in the exercise of their professional judgement.